| Preparation Instructions For The Loose End Of Jacketed Interlock Armor |
|||||||
1. Prior to terminating into your equipment, determine the length needed for the exposed leads plus 3 convolutions of cable armor |
|||||||
![]() |
|||||||
2. Go to the point on the cable where the armor will be cut and strip the jacket off approximately 6 convolutions |
|||||||
![]() |
|||||||
3. Secure the section of the armor by running bonding adhesive in the channels of approximately 4 convolutions, starting next to the PVC jacket |
|||||||
![]() |
![]() |
||||||
4. Allow the bonding adhesive to set at least 1-3 minutes, or until dry and not sticky |
|||||||
5. Cut the armor between the 3rd and 4th convolution to expose the leads, making sure there are 3 convolutions before and 3 convolutions after your cut |
|||||||
![]() |
|||||||
6. Remove the excess jacket and armor |
|||||||
Glue Recommendations:Cyanoacrylate Ester Adhesives* |
|||||||
*We recommend Duro® Super Glue and Loctite® Super Glue by Henkel Consumer Adhesives |
|||||||
Please note these instructions are recommendations only, neither seller nor manufacturer shall be liable for any injury, loss or damage, direst or consequential, arising out of the use of these products. American Connectors shall not be held liable for any incidental or consequential property damages or losses. |
|||||||